SUBJECT:         APAR  NUMBER: PQ95747
 
REFERENCE:  AREA:     TPFDF CENTRAL DATABASE ROUTINES
            SEGMENT:  UF1B13     - RELEASE:  TPFDF (Assembler)
            SEGMENT:  UWA113     - RELEASE:  TPFDF (Assembler)
 
 
Pre-requisite APARs are (TPF only) :
FOR SEGMENT UF1B13     (Assembler) - REL TPFDF
      PN35100 PN49889 PQ23489 PQ42097 PQ32210
FOR SEGMENT UWA113     (Assembler) - REL TPFDF
 PQ32210  PQ94935  
To be applied in the order listed for each segment.
 

ABSTRACT OF PROBLEM
___________________
TPFDF  database  definitions  (DBDEFs) which are used by the TPF
product should be contained in a segment shipped with TPF.
 

COMMENTS ON PROBLEM
___________________
Currently, whenever the TPF product creates a  new  TPFDF  data-
base,  both  a  TPF  and TPFDF APAR are required.   If the DBDEF
statements for TPFDF databases used by TPF were contained  in  a
TPF segment, then only a TPF APAR would be needed.
 

SOLUTION
________
TPF  continuous data collection (CDC) APAR PJ29925 created a new
TPF database and a new TPF segment,  UF1T.    Segment  UWA1  was
updated  to  call UF1T when building the DBDEF tables during TPF
restart or processing the ZUDFM DEF INIT command.
 
Additionally, other DBDEFs for TPFDF databases used by  the  TPF
product  were  moved  from  segment  UF1B  to  UF1T.   Also, the
MDBF/non-MDBF paths were removed in UF1B since the  DBDEF  defi-
nitions in both paths were the same.
 

DEPENDENCIES
____________
 
Related Segments Affected By This APAR.
_______________________________________
 
Segments to be assembled or compiled:
 
Segments to be link edited:
 
Load Modules to be loaded:
 
Migration Considerations
========================
 
This  APAR  affects TPF customers only.  However, ALCS customers
should apply this APAR to stay current on maintenance.
 
Along with this APAR, TPF customers must apply co-requisite TPF APAR
PJ29925 (CDC).  Before using any of the new function introduced with
CDC a ZUDFM DEF INIT command must be entered.
 
 