IBM®
Skip to main content
    United States [change]      Terms of use
 
 
   
     Home      Products      Services & solutions      Support & downloads      My account     
     
  TPF : Support : Maintenance : TPFDF
SUBJECT:         APAR  NUMBER: PQ50700
 
REFERENCE:  AREA:     TPFDF RECOUP ROUTINES
            SEGMENT:  BGAF13     - RELEASE:  TPFDF (C)
            SEGMENT:  BGAG13     - RELEASE:  TPFDF (C)
            SEGMENT:  BGAK13     - RELEASE:  TPFDF (C)
            SEGMENT:  BGA213     - RELEASE:  TPFDF (C)
            SEGMENT:  BGA713     - RELEASE:  TPFDF (C)
            SEGMENT:  BGA813     - RELEASE:  TPFDF (C)
            SEGMENT:  IRCMDF13   - RELEASE:  TPFDF (Dsect)
            SEGMENT:  IRDIDF13   - RELEASE:  TPFDF (Macro)
            SEGMENT:  UFED13     - RELEASE:  TPFDF (Assembler)
            SEGMENT:  UFE113     - RELEASE:  TPFDF (Assembler)
            SEGMENT:  UFE313     - RELEASE:  TPFDF (Assembler)
            SEGMENT:  UFE413     - RELEASE:  TPFDF (Assembler)
            SEGMENT:  UF1F13     - RELEASE:  TPFDF (Assembler)
 
 
Pre-requisite APARs are (TPF only) :
FOR SEGMENT BGAF13     (C)         - REL TPFDF
 PQ42097  
FOR SEGMENT BGAG13     (C)         - REL TPFDF
 PQ42097  
FOR SEGMENT BGAK13     (C)         - REL TPFDF
 PQ42097  
FOR SEGMENT BGA213     (C)         - REL TPFDF
 PQ42097  
FOR SEGMENT BGA713     (C)         - REL TPFDF
 PQ42097  PQ47054  
FOR SEGMENT BGA813     (C)         - REL TPFDF
 PQ42097  PQ44627  
FOR SEGMENT IRCMDF13   (Dsect)     - REL TPFDF
 PQ36341  
FOR SEGMENT IRDIDF13   (Macro)     - REL TPFDF
      PN38611 PN59160
FOR SEGMENT UFED13     (Assembler) - REL TPFDF
 PQ32210  
FOR SEGMENT UFE113     (Assembler) - REL TPFDF
      PN39333 PN43085 PN59160 PN63465 PN86542 PQ17413 PQ32210
FOR SEGMENT UFE313     (Assembler) - REL TPFDF
      PN43085 PN86542 PQ32210
FOR SEGMENT UF1F13     (Assembler) - REL TPFDF
 PQ23489  PQ23871  PQ36341  
To be applied in the order listed for each segment.
 
ABSTRACT OF PROBLEM
___________________
TPFDF support for 32-Way Loosely Coupled.
 
COMMENTS ON PROBLEM
___________________
Several  TPFDF  segments  require updates to support the changes
made for TPF 32-way loosely coupled  support.  The  use  of  bit
masks  was replaced with ordinal numbers to represent as many as
32 processors in a complex for TPFDF recoup  code.  Furthermore,
for  utilities that use partitions to represent processors (such
as TPFDF CRUISE and data collection), the number  of  partitions
needs  to  be  adjusted  when  these  utilities  are  run on TPF
systems.
 
 
SOLUTION
________
Several TPFDF recoup segments were adjusted to pass  an  ordinal
number  to SIPCC. For TPF systems only, the number of partitions
used by TPFDF data collection was changed to  be  equal  to  the
number  of  processors  generated  in  the complex, plus one for
totals. For TPFDF CRUISE, the number of partitions  was  changed
to  be  equal  to  the  number  of  processors  generated in the
complex. None of these changes impact ALCS systems.
 
DEPENDENCIES
____________
 
Related Segments Affected By This APAR.
_______________________________________
 
Segments to be assembled or compiled:
UF1A UF1F
 
Segments to be link-edited:
BGA2 BGA7 BGA8 BGAF BGAG BGAK
 
Load Modules to be loaded:
BGA2 BGA7 BGA8 BGAF BGAG BGAK
 
Migration Considerations
========================
For TPF customers, TPF APAR PJ27785 is a co-requisite APAR
and must be applied concurrently with this APAR.
For ALCS customers, this APAR should be applied to stay
current with maintenance.
 
TPF users must do the following when installing this APAR:
 
1.  Load this APAR to all processors defined in the complex.
 
2.  Enter ZUDFM OAI/DBTAB/INIT from each processor.
 
3.  Enter ZUDFM OAINIT ID/FDE5 twice in succession.
 
As a result of this procedure, all historical data collection
information will be lost.
 
Furthermore, when the number of processors defined in the complex
changes at any time in the future, the following must be done:
 
1.  Reassemble UF1A and UF1F, and load them to the system.
 
2.  Enter ZUDFM OAI/DBTAB/INIT from each processor.
 
3.  Enter ZUDFM OAINIT ID/FDE5 twice in succession.
 
Again, as a result of this procedure, all historical data collection
information will be lost.
 
-- END APAR PQ50700
 
 
 