TPF : Support : Maintenance : TPFDF
 |
SUBJECT: APAR NUMBER: PK32378
REFERENCE: AREA: TPFDF RECOUP ROUTINES
SEGMENT: BRCJ13 - RELEASE: TPFDF (Assembler)
SEGMENT: BRC213 - RELEASE: TPFDF (Assembler)
SEGMENT: BRC913 - RELEASE: TPFDF (Assembler)
Pre-requisite APARs are (TPF only) :
FOR SEGMENT BRCJ13 (Assembler) - REL TPFDF
PN35160 PN39186 PN41620 PN49704 PN44448 PN51644 PN67252
PN78979 PQ10797 PQ42097 PQ49400 PQ56724 PQ57571 PQ59822
PQ61996 PK15674
FOR SEGMENT BRC213 (Assembler) - REL TPFDF
PN40344 PN63712 PN63945 PQ42097 PQ49400 PQ57527 PQ56724
PQ57571 PQ68111 PQ69687 PQ69685 PQ65349 PQ74483 PQ82286
PQ83930 PQ80726 PK02459
FOR SEGMENT BRC913 (Assembler) - REL TPFDF
PN35160 PN35161 PN39186 PN40446 PN40506 PN40783 PN49889
PN44448 PN51087 PN60595 PN63714 PN72208 PN81528 PN91687
PQ00810 PQ42097 PQ49400 PQ74483 PQ75887 PQ90430 PQ99312
PQ80726
To be applied in the order listed for each segment.
ABSTRACT OF PROBLEM
___________________
Possible CTL-C dump during Recoup when DBDEF is missing or
incomplete.
COMMENTS ON PROBLEM
___________________
In the situation when RECOUP finds a reference for an ID that is
not defined in DBDEF it issues an OPR-141302 dump and writes an
entry to the log file GR0ZSR. It also sets the abort bit (BK0PHB
BIT0) to indicate that Recoup needs to be aborted. However, if
the &DFRECAB global variable in DBLCL macro is set to 1, the
abort bit is not set and RECOUP continues. This could lead to a
CTL-C dump (no working storage) because of streaming OPR-141302
dumps. The same applies to the situation where a referenced ID
does not have a RECOUP subtable defined causing streaming
OPR-141303 dumps.
SOLUTION
________
Pre-requisite TPF APAR PJ31628 defines a new savearea in the
RECOUP keypoint to save up to 5 IDs whose DBDEFs are missing or
do not have RECOUP subtables.
Segment BRC9 was updated to add up to 5 new ID/File Version to
this to this savearea for which dump OPR-141302 or OPR-141303may
have occurred. Also, an indicator is set so that any subsequent
dumps for the same ID/File Version has to be suppressed. If more
than 5 record IDs/File Versions are causing these dumps, the
indicator is not set and their dumps and log entries are not
suppressed.
Segments BRC2 and BRCJ are modified so that the log file is
updated only if this indicator is set.
DEPENDENCIES
____________
Related Segments Affected By This APAR.
_______________________________________
Segments to be assembled or compiled:
Segments to be link edited:
Load Modules to be loaded:
Migration Considerations
========================
TPF APAR PJ31628 is a pre-requisite for this APAR and must be installed
first.
-- END APAR PK32378
Click on Link(s) to Download File(s)
Download file(s):
Login once to access server, leave window open, then
click on link(s) below.
|
|
|
|
|
|