Skip to: Abstract | Comments | Solution | Migration | Download
APAR NUMBER: PJ32343 PRODUCT: TPF4 FUNCTIONAL AREA: CONTINUOUS DATA COLLECTION (CDC) SHIPPED IN PUT: 23 ABSTRACT: CDC Client creates a long-running ECB in program CTS7 APAR CONTENTS: FEATURE TYPE STATUS NAME PREREQUISITE APARS: To be applied in order listed. None. COMMENTS: Upon starting, the CDC Client opens a connection to the CDC real-time MQ queue on TPF for reading real-time data. The connection to the real-time queue remains open for the life of the client. An MQ ECB exists on TPF for the queue connection as long as the connection is open. The result is a long-running ECB on TPF which will prevent ZOLDR ACCEPTs from completing. SOLUTION: The solution is for the CDC Client to limit the time it will keep a connection open to the CDC real-time MQ queue on TPF. The maximimum time is set to 30 seconds. This change requires users to download the latest version (Version 1.4.8) of the CDC client at: http://www.ibm.com/software/htp/tpf/download/tools.htm. DEPENDENCIES SEGMENTS TO BE ASSEMBLED OR COMPILED: None. SEGMENTS TO BE LINK EDITED: None. COREQS: None. MIGRATION CONSIDERATIONS: None. UPDATED INFORMATION UNITS: None. See your IBM representative if you need additional information. DOWNLOAD INSTRUCTIONS: http://www.ibm.com/software/htp/tpf/pages/maint.htm -- END APAR PJ32343
Download file(s): Login once to access server, leave window open, then click on link(s) below. Source