APAR NUMBER:  PJ32343                         
PRODUCT:  TPF4
FUNCTIONAL AREA:  CONTINUOUS DATA COLLECTION (CDC)
SHIPPED IN PUT:  23
 

ABSTRACT:
CDC Client creates a long-running ECB in program CTS7
 
APAR CONTENTS:
FEATURE   TYPE                STATUS    NAME                              
 
PREREQUISITE APARS:  To be applied in order listed.
None.
 
COMMENTS:
Upon starting, the CDC Client opens a connection to the CDC
real-time MQ queue on TPF for reading real-time data. The
connection to the real-time queue remains open for the life of
the client. An MQ ECB exists on TPF for the queue connection as
long as the connection is open. The result is a long-running
ECB on TPF which will prevent ZOLDR ACCEPTs from completing.
 

SOLUTION:
The solution is for the CDC Client to limit the time it will
keep a connection open to the CDC real-time MQ queue on TPF.
The maximimum time is set to 30 seconds.

This change requires users to download the latest version
(Version 1.4.8) of the CDC client at:
http://www.ibm.com/software/htp/tpf/download/tools.htm.
 
 

DEPENDENCIES
 
SEGMENTS TO BE ASSEMBLED OR COMPILED:
None.
 
SEGMENTS TO BE LINK EDITED:
None.
 
COREQS:
None.
 

MIGRATION CONSIDERATIONS:
None.
 