APAR NUMBER: PJ32131 PRODUCT: TPF4 FUNCTIONAL AREA: CONTINUOUS DATA COLLECTION (CDC) SHIPPED IN PUT: 22 ABSTRACT: CPU lists length across all I-stream is incorrect in data reduction report APAR CONTENTS: FEATURE TYPE STATUS NAME Base PLI Changed source/ol/base/jra2.pli Base PLI Changed source/ol/base/jrs3.pli PREREQUISITE APARS: To be applied in order listed. Base PLI Changed source/ol/base/jrs3.pli PJ25706(09) PJ26146(10) PJ26188(10) PJ26357(11) PJ26575(11) PJ26713(11) PJ26707(11) PJ26687(11) PJ26779(12) PJ26889(12) PJ27358(13) PJ27083(13) PJ27784(14) PJ28097(15) PJ28195(16) PJ28435(16) PJ28765(17) PJ28870(17) PJ29507(18) PJ29607(19) PJ29961(19) PJ30133(20) PJ30156(20) PJ31299(21) PJ31808(22) PJ31898(22) Base PLI Changed source/ol/base/jra2.pli PJ25314(09) PJ25406(09) PJ25507(09) PJ25706(09) PJ25780(09) PJ26188(10) PJ26357(11) PJ25840(11) PJ26575(11) PJ26713(11) PJ26707(11) PJ26743(12) PJ26889(12) PJ27023(12) PJ27083(13) PJ27395(14) PJ27462(14) PJ27784(14) PJ28097(15) PJ28195(16) PJ28435(16) PJ28765(17) PJ28549(17) PJ29523(18) PJ29607(19) PJ29776(19) PJ29833(19) PJ29961(19) PJ30202(19) PJ30133(20) PJ30156(20) PJ30854(20) PJ31090(21) PJ31786(22) PJ31898(22) COMMENTS: In order to compute minimum and maximum length of CPU lists (CROSS, READY, INPUT, DEFER) across all I-streams, data reduction sums minimum and maximum list length values for every I-stream. However, minimum and maximum values for different I-streams most probably occur during different data collection intervals. Thus, CPU minimum and maximum list length for all I-streams can be incorrect in the data reduction report. SOLUTION: Segments JRA2 and JRS3 have been updated to sum minimum and maximum CPU list lengths across all I-streams for every interval. Then these sums compared in order to find minimum and maximum CPU list length values for every CPU list for the data collection episode. These minimum and maximum values are displayed in the data reduction report. DEPENDENCIES SEGMENTS TO BE ASSEMBLED OR COMPILED: None. SEGMENTS TO BE LINK EDITED: dataread.exe COREQS: None. MIGRATION CONSIDERATIONS: Maximum values for CPU list lengths for all I-streams displayed in data reduction can decrease sharply after this APAR is applied. UPDATED INFORMATION UNITS: None. See your IBM representative if you need additional information. DOWNLOAD INSTRUCTIONS: http://www.ibm.com/software/htp/tpf/pages/maint.htm -- END APAR PJ32131
Download file(s): Login once to access server, leave window open, then click on link(s) below. Source