Skip to main content

TPF : Support : Maintenance TPF : Support : Maintenance

Skip to: Abstract | Comments | Solution | Migration | Download

APAR NUMBER:  PJ31716                         
PRODUCT:  TPF4
FUNCTIONAL AREA:  CONTINUOUS DATA COLLECTION (CDC)
SHIPPED IN PUT:  21
 

ABSTRACT:
LODIC DATA COLLECTED BY CDC IS INCOMPLETE.
 
APAR CONTENTS:
FEATURE   TYPE                STATUS    NAME                              
Base      Assembler           Changed   source/rt/base/cdcr.asm
 
PREREQUISITE APARS:  To be applied in order listed.
Base      Assembler           Changed   source/rt/base/cdcr.asm
 PJ27095(12)  PJ27343(13)  PJ28097(15)  PJ29811(19)    
 PJ29925(19)  PJ30503(20)  PJ30701(20)  PJ30946(20)  
 
COMMENTS:
Only the 1st lodic priority class of 8 is collected by CDC. The
rest are set to a default value of zero.
 

SOLUTION:
Change the CDC code to collect all 8 lodic priority classes.
 
 

DEPENDENCIES
 
SEGMENTS TO BE ASSEMBLED OR COMPILED:
None.
 
SEGMENTS TO BE LINK EDITED:
cdcp40.exe (Shipped in Tar File)
 
COREQS:
None.
 

MIGRATION CONSIDERATIONS:
None.
 
UPDATED INFORMATION UNITS:
None.
 
See your IBM representative if you need additional information.
 

DOWNLOAD INSTRUCTIONS:
http://www.ibm.com/software/htp/tpf/pages/maint.htm

 
-- END APAR PJ31716
      



Download file(s): Login once to access server, leave window open, then click on link(s) below. Listing Binary Source