Skip to: Abstract | Comments | Solution | Migration | Download
APAR NUMBER: PJ30253 PRODUCT: TPF4 FUNCTIONAL AREA: CONTINUOUS DATA COLLECTION (CDC) SHIPPED IN PUT: 20 ABSTRACT: With APAR PJ29925 applied, CDCP takes a CTL-E1 when cycling down from NORM state to 1052 state. APAR CONTENTS: FEATURE TYPE STATUS NAME Base Copy Changed source/cp/base/ccit40.cpy Base C Changed source/rt/base/cdcp.c PREREQUISITE APARS: To be applied in order listed. Base Copy Changed source/cp/base/ccit40.cpy PJ25294(09) PJ25781(09) PJ25981(10) PJ26966(12) PJ28649(17) PJ29160(18) PJ29573(19) PJ29925(19) PJ30137(19) Base C Changed source/rt/base/cdcp.c PJ27095(12) PJ27775(15) PJ28097(15) PJ29925(19) PJ30137(19) PJ30215(20) PJ30233(20) COMMENTS: CDCP takes a CTL-E1 system error when cycling down from NORM state to 1052 state. Although a check is made to ensure that the system is in NORM state in CCNUCL (ccit40.cpy) before starting CDCP execution, a check is not done for cycle down. SOLUTION: Ensure that the cycle down bit in CCNUCL (ccit40.cpy) is checked before starting CDCP. DEPENDENCIES SEGMENTS TO BE ASSEMBLED OR COMPILED: ccnucl.asm SEGMENTS TO BE LINK EDITED: cps040.exe cdcp40.exe (Shipped in Tar File) COREQS: None. MIGRATION CONSIDERATIONS: None. UPDATED INFORMATION UNITS: None. See your IBM representative if you need additional information. DOWNLOAD INSTRUCTIONS: http://www.ibm.com/software/htp/tpf/pages/maint.htm -- END APAR PJ30253
Download file(s): Login once to access server, leave window open, then click on link(s) below.Source Listing Binary