SUBJECT:         APAR  NUMBER: PJ27871
 
REFERENCE:  AREA:     VISUALAGE ASSEMBLER DEBUGGER
            SEGMENT:  CUDU40     - RELEASE:  TPF4  (Copy)
 
 
Pre-requisite APARs are:
FOR SEGMENT CUDU40     (Copy)      - REL TPF4
 PJ25981  PJ26008  PJ26600  PJ26784  
 PJ26923  PJ26951  PJ27383  
 PJ27441  PJ27563  
To be applied in the order listed for each segment.

ABSTRACT OF PROBLEM
___________________
VATPF - NO DEBUG USER OPTION NOT RESET
 

COMMENTS ON PROBLEM
___________________
When the CE3DBCR field of the ECB is set with CE3_NO_DEBUG, this
indicates that the debugger should not debug the ECB.
 

SOLUTION
________
In CUDU, the base register that was used incorrectly was changed
to the correct base register at label CUDU_RESET.  Base register
10 was changed to base register 5.
 
DEPENDENCIES
____________
 
Related Segments Affected By This APAR.
_______________________________________
 
Segments to be assembled or compiled:
- CCVAGE40.
 
Segments to be link-edited:
- CPS040.
 
Load Modules to be loaded:
- None.
 
Migration Considerations
========================
- None.
 
-- END APAR PJ27871
 
 
 